Shielded Room

Regulations against eletromagnetic interfarence is increasing year by year.
Hillstec is making efforts on developing and manufacturing cost effective but high quality shielded rooms to answer to the needs especially from the Medical Equipments EMC field.
Our shielded rooms are adopting modular-panel method so that it is easy to build up. It is also easy to take apart so that rebuilding at other place is also easy to do.


Shielded room for electro-static discharge (ESD)

Shielded room for electro-static discharge (ESD)

Shielded room for electro-static discharge (ESD) based on IEC61000-4-2.
The dimensions of the shielded room is designed based on the size of the table for ESD tests.

Basic dimensions
External
materials

Jointed panel construction
Fully Galvanized iron plate with Alminium frame.

Inner
arrangement

Fully Galvanized iron plate or cloth covered

Floor
arrangement

Tile carpet/P-tile/Linoleum(water proof) selectable

Electricity

  • Single phase 200VAC for primary(typical)
  • Single phase 100VAC - 240VAC for secondary (inside shielded room)

Shielded
door

Clear opening size: 900(W) x 2000(H)mm

TOP


Shielded room for conducted emission (CE) measurements

Shielded room for conducted emission (CE) measurements

Shielded room for conducted emission (CE) measurements based on CISPR22/EN55022.
The basic desing is the same as the one for ESD tests but there is a connector panel prepared on the wall so that the measurement equipments can be installed outside the shielded room.

Basic dimensions
External
materials

Jointed panel construction
Fully Galvanized iron plate with Alminium frame.

Inner
arrangement

Fully Galvanized iron plate or cloth covered

Floor
arrangement

Tile carpet/P-tile/Linoleum(water proof) selectable

Electricity

  • Single phase 200VAC for primary(typical)
  • Single phase 100VAC - 240VAC for secondary (inside shielded room)

Shielded
door

Clear opening size: 900(W) x 2000(H)mm

TOP


Shielded room for Clamp measurements (conducted power measurements)

Shielded room for Clamp measurements (conducted power measurements)

Large scale shielded room that is designed for absorbing clamp measurements (CISPR 16-1-3).
This shielded room has longer length than the ones for ESD tests and can install 6m clamp rail inside the shielded room.

Basic dimensions
External
materials

Jointed panel construction
Fully Galvanized iron plate with Alminium frame.

Inner
arrangement

Fully Galvanized iron plate or cloth covered

Floor
arrangement

Tile carpet/P-tile/Linoleum(water proof) selectable

Electricity

  • Single phase 200VAC for primary(typical)
  • Single phase 100VAC - 240VAC for secondary (inside shielded room)

Shielded
door

Clear opening size: 900(W) x 2000(H)mm x2

TOP